Hot Product
- Hydrocyclone Group
Hydrocyclone group is widely used in coal preparation plant...
- Slurry Pump
Slurry pump is mainly used in mining, power plant, dredging, metallurgy...
- Polyurethane Dewatering Screen Panel
In addition to the performance of...
The Method To Solve The Lack Of Vibration Motor
Date: 2023-03-30 From: Longding Author: admin
For various reasons, the three-phase vibration motor lacks a live wire, which is called a missing item. If the protection device is not installed, the consequence of the lack of items is to burn the vibration motor directly. Therefore, when using a vibration motor, it is necessary to have a contactor and a thermal relay for protection. When there is a phase loss, the contactor can protect two of the phases from disconnecting automatically when the phase is missing. The thermal relay can cut off the contactor in case of overcurrent to protect the vibrating motor.
The solution to the lack of vibration motor
1. Poor contact with the switch
The moving and static contacts of the switch trigger are connected together so that the three-phase contacts are asynchronous and lose phase. Or the trigger is not suitable for the vibration motor.
Solution: Replace the trigger to match the vibration motor properly, and it will be solved.
2. Fuse blown makes phase loss
Fuses are not suitable or pressed properly. The main circuit of the motor is grounded or short-circuited so that the fuse blows and the phase is lost.
Solution: Replace with the appropriate fuse. The installation method should be correct and checked regularly.
3. Inappropriate melt capacity
Small capacity. The fuse is easily blown by the impact of the current when starting.
Solution: Choose the fuse correctly according to the rated current, or choose a fuse with a larger heat-resistant capacity.
4. Contact damage
Humidity, vibration, and corrosive gas in the air will cause the contact to be oxidized and then melted and damaged. Or use for a long time, resulting in serious wear of the contacts.
Solution: Choose an original that suits the environment. Check regularly and replace in time if there is any problem.
5. Bad wire contact
Improper installation, wire breakage, or damage by external force causes phase loss.
Solution: Strictly implement standard installation.
6. Winding failure
The running time of the motor is too long, the resistance welding of the coil is poor or desoldered, and the contact between the lead ring and the coil is poor, which causes the magnetic field of the motor to run poorly.
Solution: Repair or directly replace the vibration motor.
If the vibration motor wants to be used for a long time, it needs regular maintenance and maintenance. Choosing a brand vibration motor is an important reason to ensure the normal operation of the vibration motor and machinery.
Previous:How To Choose a Suitable Vibration Motor?
Next:The Installation Method Of Vibrating Motor In Vibrating Screen
Leave a Message
Here you can submit any questions and we will get back to you as soon as possible. We will not disclose the information you submit to anyone, please rest assured.
Inquiry